Tests/Reports:

Cable Specifications:

Mechanical Specifications:

Shock100 g’s with no discontinuities > 1 µs
Vibration15 g’s with no discontinuities > 1 µs
Operating Temperature-55ºC to 125ºC
HumidityEIA-364-3 I, Test Cond A Omit Steps 7A & 7B
Durability2000 mating cycles minimum

Material Specifications:

ContactCopper Alloy per MIL-DTL-83513
Contact FinishGold per ASTM B488, Type II, Class 1.27, Code C Over Nickel Underplate

Electrical Specifications:

Contact TypeCable-to-CableEdge LaunchThrough Hole
Frequency RangeDC to 20 GHzDC to 20 GHzDC to 10 GHz
 GatedNon-GatedGatedNon-GatedGatedNon-Gated
VSWRDC-10 GHz1.2:11.3:11.1:11.3:11.3:11.55:1
10-20 GHz1.25:11.4:11.3:11.6:1N/AN/A
Return LossDC-10 GHz-27 dB-16 dB-23 dB-19 dB-15 dB-13 dB
10-20 GHz-25 dB-15 dB-19 dB-13 dBN/AN/A
Insertion LossDC-10 GHz-0.7 dB-1.7 dB-0.7 dB-1.5 dB-2.0 dB-2.9 dB
10-20 GHz-1.0 dB-2.3 dB-1.9 dB-3.0 dBN/AN/A
ImpedanceTR=100ps50 Ω ± 2.5 Ω50 Ω ± 2.5 Ω50 Ω ± 5 Ω